Barcode Handy TerminalBHT-604BWUser’s ManualALP+=%#&$:,*/-SPACE
ix BHT-604BW Handling the CU If smoke, abnormal odors or noises come from the CU, immediately unplug the AC adapter from the wall socket or CU and
86 BHT-604BW Setting the DHCP 1. Select “3: DHCP” at the SET TCP/IP menu and then press the ENT key. The SET DHCP screen displays as shown on the
87 Barcode Handy Terminal 4.5.6 BHT Operation Test (TEST Menu) Use the following procedure to perform a BHT operation test. 1. Select “5: TEST” at t
88 BHT-604BW [1] Barcode reading test Use the following procedure to perform a barcode reading test. 1. Select “1: BARCODE” at the TEST menu and the
89 Barcode Handy Terminal Setting the Barcode reading Test Options When performing the barcode reading test, press the F1 key to display the screen
90 BHT-604BW [2] Memory test Use the following procedure to perform a memory test. 1. Select “2: MEMORY” at the TEST menu and then press the ENT key
91 Barcode Handy Terminal [3] Beeper scale test Use the following procedure to perform a beeper scale test. 1. Select “3: BEEPER” at the TEST menu a
92 BHT-604BW [5] LCD and indicator LED tests Use the following procedure to perform an LCD and indicator LED test. 1. Select “5: LCD” at the TEST me
93 Barcode Handy Terminal 4. Press the ENT key. The entire screen turns a lighter shade of gray. Press the BS key to return to the previous screen.
94 BHT-604BW 7. Press the ENT key. The entire screen turns red, and at the same time, the indicator LED turns red. Press the BS key to return to the
95 Barcode Handy Terminal 10. Press the ENT key. A 1-dot thick frame displays around the screen. Press the BS key to return to the previous screen.
x Barcode Handy Terminal To System Designers: When introducing BHTs in those systems that could affect human lives (e.g., medicines management sy
96 BHT-604BW [6] File test Use the following procedure to perform a file test. 1. Select “6: FILE” at the TEST menu and then press the ENT key. The
97 Barcode Handy Terminal [7] ommunication test wing procedure to perform a communication test. 1. Select “7: COMMUNICATION” at the TEST menu and th
98 BHT-604BW 3. the master an error occurs, the tested slave BHT beeps three times and displays the creen on the right. he meanings of the error co
99 Barcode Handy Terminal Connector Communication Test plug) as s 2. elect “2: CONNECTOR” at the TEST COMMUNICATION menu nd then press the ENT
100 BHT-604BW [8] Key-entry, beeper and vibrator test Use the following procedure to perform a key entry, beeper and vibrator test. TEST menu and t
101 Barcode Handy Terminal [9] PING test Use the following procedure to run the PING test. 1. Select “9: PING” at the TEST menu and then press the E
102 BHT-604BW Upon completion of the PING test, the screen displays as shown on the und during the PING test. ok ed in center of screen)right.
103 Barcode Handy Terminal 1. elect “2: SET PING” at the TEST PING menu and then press the NT key. [2:DATA SIZpecifies[3:INTERVAL]: Specifies the
104 BHT-604BW PING Echo Request Transmission Timing (SEND TYPE) Two types of echo request send timings are available: TYPE 1 and TYPE 2. After sendin
105 Barcode Handy Terminal 1. elect “3: SET DEVICE” at the TEST PING menu and then press the ress the C key to return to the TEST PI“3: SET DEV
xi BHT-604BW Handling the CU Never disassemble or modify the CU; doing so could result in an accident such as fire or malfunction. Never put t
106 BHT-604BW 4.5.7 System Information (SYSTEM INFORMATION Menu) [1] Displaying the BHT system information Use the following procedure to display t
107 Barcode Handy Terminal [1] Functions for which licenses have been registered () 1. Use the cursor keys ([▲] [▼]) to highlighas been registered,
108 BHT-604BW [2] CU-611 System Information Display Use the following procedure to display CU-611 system information. 1. Place the BHT on the CU-611
109 Barcode Handy Terminal 4.5.8 iles by FTP (FTP MENU) Use the following procedure to download and upload files by FTP. MENU and then press scre
110 BHT-604BW 2. and then press the ENT key. e with the numerical keys and dot key. ress the SF and the BS key to change the entry mode (numerical
111 Barcode Handy Terminal [ ] 2 Uploading by FTP exist. layed at the FTP client initial ress the M1 key to return to the previous screen. 2. en pr
112 BHT-604BW 3. Enter the directory and file name, or select a file, and then press the ENT key. Press the C key to return to the FTP MENU screen.
113 Barcode Handy Terminal FTP Download/Upload Messages When the BHT is uploading or downloading files by FTP, the following messages will appear at
114 BHT-604BW Response Messages from the FTP server w. estart marker pady in pconnection a transferring. atus okay s ction. d okaye to is m status
115 Barcode Handy Terminal 4.5.9 to perform wireless communication settings. 1. Se M MENU and then press the ENT key. Th [1 rforms wireless parameter
xii Barcode Handy Terminal Declaration of Conformity For European Union English: Hereby, DENSO WAVE INCORPORATED, declares that this BHT-604BW contai
116 BHT-604BW Wireless Network Parameter Settings 1. K menu and then press the ENT key. : SSID]: Displays the current Service Set ID. C s Com
117 Barcode Handy Terminal Wireless Security Settings 1. Select “2: SECURITY” at the SET RF PARAMETER menu and then press the ENT key. The screen
118 BHT-604BW Wireless Security None Mode WEP can be used with the Wireless security None mode. ting is the encryption key, which can be set fro
119 Barcode Handy Terminal 4. [3] [4] [5]) to Select 40 (40 bits) or 128 (128 bit). as been set, 40 will be highlighted. : KEY]: 5. al key ([1])
120 BHT-604BW 8. Press the C key to return to the SET RF PARAMETER menu. n WEP key, and therefore the WEP kebe stored in a safe location. When not
121 Barcode Handy Terminal ireless Security 1x Supplicant Mode EAP authentication can be used with wireless security 1x Supplicant mode. 1. elect
122 BHT-604BW 5. Use the numerical keys to enter an ID and press the ENT key. ey. ress the C key to delete all entries made. 6. se the cursor keys
123 Barcode Handy Terminal ireless Security WPA-1x Mode EAP authentication and an encryption system can be used with wireless security WPA-1x mode
124 BHT-604BW 5. Use the numerical keys to enter an ID and press the ENT key. ey. ress the C key to delete all entries made. 6. s ▲] ]) to highress
125 Barcode Handy Terminal t [2: WPA CIPHER] and then press the ENT keyys as shown on the right. . IPHER MODE] is highlighted and then select . Sel
xiii BHT-604BW Polski: Niniejszym, DENSO WAVE INCORPORATED, oświadcza, że ten BHT-604BW zawiera moduł łączności bezprzewodowej dla sieci LAN (typu: N
126 BHT-604BW 3. Ensure that [1: PRE SHARED KEY] is highlighted and then press the The mode changes to entry mode and the cursor displays. 4. e res
127 Barcode Handy Terminal 2. Use the cursor keys ([▲] [▼]) or numerical key ([1]) to highlight [1: AUTH PARAM (EAP)] and then press the ENT key. Th
128 BHT-604BW 8. Use the cursor keys ([▲] [▼]) or numerical key ([4]) to highlight [4press the ENT key. :rsor displays. 9. ss the ENT key. nge the
129 Barcode Handy Terminal ireless Security WPA2-PSK Mode PSK authentication and an encryption system can be used with wireless security WPA2-PSK
130 BHT-604BW 8. ialization 1. elect “3: INITIALIZE” at the SET RF PARAMETER menu and then as hoo initiali wireless parameters: se the cursor key
131 Barcode Handy Terminal [2] Site Survey Menu Select “2: SITE SURVEY” at the RF MENU and then press e ENT key. own on the right. 2. ation statu
132 BHT-604BW 4.5.10 files or data files stored in the FLASH ROM. 1. ENU. he DELETE FILE menu screen displays as shown on the right. ress the C ke
133 Barcode Handy Terminal 4.5.11 Deleting Font Files (DELETE FDelete font files stored in the FLASHILE Menu) ROM. If a equal to the can be secured.
134 BHT-604BW To delete font files: Use the cursor keys ([▲] [▼]) or numerical key ([1]) to highlight [1: Yes] and o return to the DELETE FILE menu.
135 Barcode Handy Terminal 4.5.12 eMETER Menu) ettg Environment Settings”. he same settings can be set at another BHT by copying the system pa comput
BHT-604BWChapter 1 Outline This chapter describes the BHT system and provides an overall outline of the BHT. 1.1 System Config
136 BHT-604BW [1] Downloading the BHT system parameter file 1. Use the cursor keys ([▲] [▼]) or numerical key ([1]) to highlight [1: en displays a
137 Barcode Handy Terminal [2] Uploading the BHT system parameter file 1. Use the cursor keys ([▲] [▼]) or numerical key ([2]) to highlight [2: UP
138 BHT-604BW 4.5.13 REMOTE WAKEUP Menu) 1. n on the right. : REMOTE WAKEUP]: Enables or disables remote wake-up. :TRANSMIT SPEED]: Sets the transm
139 Barcode Handy Terminal 4.5.14 Downloading/Uploading the System Message File (SYSTEM MESSAGE Menu) The system message file is a file (file name: “
140 BHT-604BW [1] Downloading the system message file 1. Use the cursor keys ([▲] [▼]) or numerical key ([1]) to highlight [1: r the system message
141 Barcode Handy Terminal [2] Uploading the system message file 1. Use the cursor keys ([▲] [▼]) or numerical key ([2]) to highlight [2: UPLOAD] an
142 BHT-604BW 4.5.15 1. he MODIFY MENU screen displays as shown on the right. : SYSTEM MODIFY]: Updates the BHT system. : CU-F/W MODIFY]: Updat
143 Barcode Handy Terminal When the Displayed File Name Differs from the BHIf the name of the file displayed at [2: FILENAME] differs fromT System
144 BHT-604BW [2] Updating the CU-611 system Update the CU-611 system after downloading the CU-611 system update file. (Refer to section ”4.2.2 CU-6
145 Barcode Handy Terminal If the System Update File Does not Exist when Updating the e file does not exist when updating the CU-611 system. m Pre
2 BHT-604BW 1.1 1System Configuration This section describes the hardware required for the barcode data collection system used by the BHT and the BH
146 BHT-604BW
BHT-604BW Chapter 5 Communication This chapter describes technical information relating to the connector communication (RS-232C
148 BHT-604BW 5.1 Connector Communication(RS-232C Interface) The BHT-604BW is equipped with a connector interface used to communicate with other dev
149 Barcode Handy Terminal 5.1.2 Interface Cable Connection Connect the BHT directly to a host computer, a modem, or a printer with a connector inter
150 BHT-604BW 5.2 IrDA Communication The BHT has a built-in IrDA communication device that enables wireless transfer of programs and data both betwe
151 Barcode Handy Terminal 5.2.1 IrDA Communication Port Transmission Speed Communicating Device Transmission Speed BHT-600 Series 9.6、19.2、38.4、5
152 BHT-604BW 5.3 Wireless Communication The BHT-604BW is equipped with a 2.4 GHz waveband wireless module. 5.3.1 Usage Precautions It may be poss
153 Barcode Handy Terminal 5.3.2 Setting Parameters Programs written in BHT-BASIC control wireless communication with commands between the BHT and ac
154 BHT-604BW EAP TYPE This is the EAP authentication method setting used for 802.1x authentication. Select PEAP or EAP-TLS. This is valid only whe
155 Barcode Handy Terminal 5.4 Basic Communication Specifications and Parameters 5.4.1 Basic Communication Specifications The table below lists commu
3 Barcode Handy Terminal Host Computer Allows you to edit, manage and download user programs and data, as well as downloading system programs. Mod
156 BHT-604BW Transmission Code and Bit Order All characters should be coded to 7 or 8-bit code for data transmission. The standard code at t
157 Barcode Handy Terminal 5.4.2 Communications Parameters In System Mode and user programs written in BHT-BASIC, you can set the communications para
158 BHT-604BW
BHT-604BW Chapter 6 Maintenance This chapter describes battery cartridge and daily procedures for taking care of the BHT and CU/CH.
160 BHT-604BW 6.1 Replacing the Battery Cartridge 6.1.1 Battery Cartridge Service Life The battery cartridge is a consumable part and should be repla
161 Barcode Handy Terminal 4. Insert the battery cover tab (1), and then close the battery cover (2) to lock the cover in position. Battery
162 BHT-604BW 6.2 Using the BHT after Long Periods Data stored in the BHT may be lost and the calendar clock may stop if the BHT is left unused for
163 Barcode Handy Terminal 6.3 Daily Maintenance 6.3.1 Proper Care of the BHT Wipe any dirt from the BHT housing, charge terminals, and BHT or batter
164 BHT-604BW
BHT-604BW Chapter 7 Error Messages This chapter describes causes and countermeasures for error messages that display during BHT use. Abou
4 BHT-604BW BHT-BASIC 4.0 Development Pack (Option) and BHT-BASIC 4.0 Transfer Utility (Option) Refer to “Software Configuration” on the following
166 BHT-604BW 7.1 System Errors The error messages that display on the screen and the causes and countermeasures to be taken if an error occurs when
167 Barcode Handy Terminal Message BHT Response Cause Countermeasure The date and time settings screen displays, awaiting entry. The c
168 BHT-604BW Message BHT Response Cause Countermeasure The message continues to display. When the BHT is turned on, no user programs
169 Barcode Handy Terminal Message BHT Response Cause Countermeasure If this error occurs, the BHT beeps five times. An error has occu
170 BHT-604BW 7.2 System Mode Errors When error messages display while running System Mode, refer to the following table and take appropriate measur
171 Barcode Handy Terminal Message BHT Response Countermeasure The current download will exceed the maximum allowable number of files
172 BHT-604BW Message BHT Response Countermeasure The memory is insufficient for setting up the BHT system parameter file or system m
BHT-604BW Chapter 8 Specifications This chapter describes the BHT-604BW specifications. 8.1 BHT-604BW Specifications ···········
174 BHT-604BW 8.1 BHT-604BW Specifications 8.1.1 Hardware Specifications Power supply (main power): Rechargeable lithium-ion battery cartridge (3.7
175 Barcode Handy Terminal 8.1.2 Barcode Specifications Supported Barcode Types Barcode Type Bar Dimensions Scan Magnification Universal product co
5 Barcode Handy Terminal 1.1.2 Software Configuration This section describes the software used for BHT Series application development and application
176 BHT-604BW 8.1.3 Reading Performance Reading Reference Position As illustrated at left, align the reading window with the center of the label (c
177 Barcode Handy Terminal *1 Under the following conditions: - Ambient illuminance: 500 Lx. (Xenon arc lamp) - Code 39, 4 digits Narrow ba
178 BHT-604BW 8.1.4 Interface Specifications IrDA Interface Specification: IrDA Ver1.3 Low Power physical layer compliant (Except transmission s
BHT-604BW Chapter 9 Appendices This chapter describes the CU-600 Series (option) specifications, and describes causes and countermeasures
180 BHT-604BW 9.1 CU-600 Specifications 9.1.1 Hardware Specifications CU-601 CU-611 CU-621 Power supply: 100/230 V AC (Using dedicated AC adapter)
181 Barcode Handy Terminal 9.1.3 Interface Specifications CU-601 The CU-601 RS-232C interface connector uses Dsub-9P. Pin. No. Signal Name Functi
182 BHT-604BW CU-611 The CU-611 has an IEEE802.3-compliant Ethernet interface port (100Base-TX). Ethernet Interface Port (RJ45 jack) on the CU-611
183 Barcode Handy Terminal 9.2 When File Transfer is Not Possible Using the Transfer Utility This section describes the causes and remedies when file
184 BHT-604BW Error No. Cause Details Remedy The Transfer Utility “Communication port” option specification is illegal. Specify the communication p
185 Barcode Handy Terminal Error No. Cause Details Remedy An attempt was made to download a BHT-BASIC 3.6 format program file (*.PD3).Use BHT-BASIC
i BHT-604BW Preface Thank you for using the BHT-604BW DENSO WAVE Barcode Handy Terminal. Please read this manual thoroughly prior to operation to en
6 BHT-604BW BHT-BASIC4.0 Transfer Utility Transfers files between the host computer and BHT at the host computer. YMODEM or BHT-Ir protocol is use
Barcode Handy Terminal BHT-604BW User’s Manual First Edition May 2008 Second Edition September 2008 Third Edition Marc
7 Barcode Handy Terminal System Mode This program is used to operate files, make system environment settings, and perform various types of tests. R
8 BHT-604BW 1.2 Component Names and Functions 1.2.1 BHT Front/Rear (1) (2) (3) (4)(5) (6) (8) (7) (11) (10) (9) (12) No. Name
9 Barcode Handy Terminal 1.2.2 Keypad The BHT key functions can be set at user programs. The diagram below shows an example of settings for each key
10 BHT-604BW No. Key Name Function and Description (8) Numerical keys Used to enter data. (9) Enter key Press to finalize entered data or execu
11 Barcode Handy Terminal 1.2.3 BHT Screen If the system display is set to ON at the system settings or in the user program, icons display at the bot
12 BHT-604BW
BHT-604BW Chapter 2 BHT Preparation This chapter describes inserting and charging the battery cartridge, turning the BHT power O
14 BHT-604BW 2.1 “BHT Preparation” Procedure Follow the steps below to prepare the BHT for use. 2.2 Inserting and Charging the Battery Cartrid
15 Barcode Handy Terminal Charging with the communication unit (CU-601, CU-611 and CU-621) or battery charger (CH-651 and CH-654) 1. Slide the ba
ii Barcode Handy Terminal Customer Registration and Inquiries Customer Registration To allow us to provide our customers with comprehensive service a
16 BHT-604BW Note Power for the CU-621 can be obtained from a USB connection port (host computer or hub),however, charging is not possible whil
17 Barcode Handy Terminal Charging with the battery charger (CH-201A and CH-704) Terminal 1. Check the battery cartridge terminals and insert the
18 BHT-604BW 4. Slide the battery cover lock (1) in the direction indicated by the arrow and remove the battery cover (2). 5. Check the batter
19 Barcode Handy Terminal Mishandling of the charger may result in charger overheating, smoke generation, blowout orcombustion. Please read the fol
20 BHT-604BW 2.2.1 Battery Power Level Indicator Confirming at the Power Level Icon The battery power level can be confirmed at the battery icon (
21 Barcode Handy Terminal 2.3 Wearing the Hand Strap Wear the hand strap to prevent the BHT from being accidentally dropped during use. 2.3.1 Attac
22 BHT-604BW 2.4 Initial Setup Turn ON the power after inserting the fully charged battery cartridge into the BHT. The date and time are not set at
23 Barcode Handy Terminal 2.5 Turning OFF the Power You can turn OFF the BHT in one of the following three methods. Normal power OFF Press the P
24 BHT-604BW 2.5.4 If the BHT Is Shut Down Abnormally If the BHT is shut down abnormally* and is left without a battery cartridge or with a discharge
25 Barcode Handy Terminal If Scandisk finds an invalid file(s), the right screen will appear. (As long as an invalid file exits, the screen display
iii BHT-604BW About this Manual Due to improvements and so on, the content of this manual may be subject to change without prior notice. The r
26 BHT-604BW About “$$BRKLST.SYS” If Scandisk finds an invalid file(s), it will automatically create the "$$BRKLST.SYS" file. To check th
BHT-604BW Chapter 3 Basic Operation This chapter describes basic operations such as barcode reading, numerical data entry and it
28 BHT-604BW 3.1 Reading Barcodes Follow the procedure below to read barcodes. 1. Turn the BHT power ON. Power key 2. Press the trigger swit
29 Barcode Handy Terminal When unable to successfully read barcodes… Cause Countermeasure Specular reflection When the light is focused on the prin
30 BHT-604BW 3.2 Numeric Data Entry Enter numeric data such as product volume with the numeric keys and Enter ( ) key. If numeric data is e
31 Barcode Handy Terminal 3.4 Changing the Default Settings The buzzer volume, vibrator, LCD screen brightness, power save settings and key backligh
32 BHT-604BW 2. Use the [▲] and [▼] cursor keys to select the item to be changed. With the start or end of the item highlighted, press [▲] or [▼] to
33 Barcode Handy Terminal 3.5 Transmitting Data Data gathered by the BHT can be transmitted to the host computer by connector communication, IrDA co
34 BHT-604BW 3.5.1 Connector Communication Connect the host computer and BHT with a dedicated interface cable (Option, Type: CBBHT-RS1000/3-9-02) and
35 Barcode Handy Terminal 3.5.2 IrDA Communication When performing data communication between BHT units Point the BHT IrDA communication ports towa
iv Barcode Handy Terminal Viewing this Manual − About the Bookmark The PDF Bookmark function can be used to jump to the Contents page. <Procedure
36 BHT-604BW 3.5.3 Wireless Communication Transmit data to host computer via the wireless LAN access point. To perform wireless communication, it is
BHT-604BW Chapter 4 System Operation This chapter describes how to initialize and update the system, start up a user program, and o
38 BHT-604BW 4.1 Initializing the BHT System By initializing the system, program files and data files downloaded to the BHT user area are deleted, a
39 Barcode Handy Terminal 4.1.1 Selecting the Memory Area to be Initialized 1. Press the Power key ( ) while holding down the SF, M1 and 0 keys to
40 BHT-604BW 4.1.2 Selecting the Message Version (English or Japanese) 1. When the screen displays as shown on the right, select the message display
41 Barcode Handy Terminal 4.1.4 Performing System Initialization 1. The screen displays as shown on the right during system initialization.
42 BHT-604BW 4.2 Updating the System 4.2.1 Updating the BHT System The BHT system update procedure is as follows. BHT System Update File Download
43 Barcode Handy Terminal 4.2.2 CU-611 System Update The CU-611 system update procedure is as follows. CU-611 System Update File Download CU-6
44 BHT-604BW 4.3 Executing User Programs User programs (application programs) can be executed using the following methods. Select the most appropria
45 Barcode Handy Terminal Several directory management program examples are given below. The names of the files used in these examples are as follows
v BHT-604BW − Searching by Word The PDF search function can be used to jump to the target page by entering words or characters related to the item be
46 BHT-604BW (Example 3) Recommended download method After system initialization, first download the program to be executed simply by pressing the
47 Barcode Handy Terminal 4.4 System Mode By starting up the BHT in System Mode and selecting each menu, the following operations can be performed i
48 BHT-604BW 4.4.2 System Mode Basic Operation Menu Selection and Display Use the following procedure to select and display each menu. Operation e
49 Barcode Handy Terminal Setting Value Selection Operation example Select the setting item with the [2] key or [▲]/[▼] keys. Use the following pro
50 BHT-604BW 4.4.3 SYSTEM MENU Configuration Menu Configuration for Items Displayed at the SYSTEM MENU Screen Select the item with the numerical key
51 Barcode Handy Terminal System Environment Setting Refer to section “4.5.5 System Environment Setting”.Testing 6 and ENT keys 7 and ENT keys 8 and
52 BHT-604BW Menu Configuration for Items Not Displayed at the SYSTEM MENU Screen Press the corresponding numerical key while holding down the SF key
53 Barcode Handy Terminal Setting Remote Wake-up Refer to section “4.5.13 Setting Remote Wake-up”. C key 4 with SF held down Download
54 BHT-604BW 4.5 SYSTEM MENU 4.5.1 Executing User Programs (EXECUTE PROGRAM Menu) Individually select and execute user programs downloaded to the BH
55 Barcode Handy Terminal 4.5.2 Downloading Files (DOWNLOAD Menu) Download files to the BHT user area from other devices such as the host computer.
vi Barcode Handy Terminal Related Documentation BHT-BASIC Programmer’s Manual (BHT-600 Series) This is an instruction manual used to create handy
56 BHT-604BW 2. Select either “1: FILE” or ”2: HT<-->HT COPY” and press the ENT key. The screen displays as shown on the right indicating that
57 Barcode Handy Terminal 5. When downloading is complete, the beeper sounds once and the scrthe right. een displays as shown on When the number of r
58 BHT-604BW 4.5.3 Uploading Files (UPLOAD Menu) Upload files stored in the BHT user area to another device. Use the following procedure to upload f
59 Barcode Handy Terminal 2. Select “1: FILE”, ”2: ALL FILES” or ”3: HT<-->HT COPY” and press the ENT key. When “1: FILE” is selected: The scre
60 BHT-604BW 4. By executing the BHT-BASIC 4.0 Transfer Utility or similar program, the screen displays as shown on the right and file uploading is c
61 Barcode Handy Terminal 4.5.4 Copying Files between 2 BHT Units Copy “all files (excluding font files)”, “setting data”, and the “date and time” s
62 BHT-604BW - Note - The following setting data is copied when copying between BHT units. LCD contrast level Beeper volume Switching between beep
63 Barcode Handy Terminal FTP option, Line delimiters (CR/LF) FTP option, Handling of line delimiters FTP option, Handling of trailing spaces in dat
64 BHT-604BW 4.5.5 System Environment Settings (SET SYSTEM Menu) Use the following procedure to set the system environment. 1. Select “4: SET SYSTEM
65 Barcode Handy Terminal [1] Setting the auto-start execution program Use the following procedure to set the auto-start execution program. 1. Selec
vii BHT-604BW SAFETY PRECAUTIONS Be sure to observe all these safety precautions. Please READ through this manual carefully. It will enable you to
66 BHT-604BW [2] Setting the message version, system status indication and screen display compatible mode Use the following procedure to set the dis
67 Barcode Handy Terminal 4. Simultaneously press the SF key and “1: MESSAGE” at the SET DISPLAY menu. The SET DISPLAY menu displays as shown on the
68 BHT-604BW System Status Indication Turning ON the system status indication displays the following icons at the bottom of the screen. Indicatio
69 Barcode Handy Terminal [4] Setting the special barcode reading parameters Use the following procedure to set the barcode reading conditions. 1. S
70 BHT-604BW “3: ITF”: Minimum number of digits to be read for ITF “4: STF”: Minimum number of digits to be read for STF “5: CODABAR”: Minimum
71 Barcode Handy Terminal Use the following procedure if necessary to change the communication environment settings. 1. Select “5: COMMUNICATION” at
72 BHT-604BW “2: PROTOCOL”: Communication protocol options setting screen Select “2: PROTOCOL” to display the screen shown on the right The highli
73 Barcode Handy Terminal “2: CONNECTOR”: Connector communication environment settings 1. Select “2: CONNECTOR” at the SET COMMUNICATION menu and
74 BHT-604BW “2: PROTOCOL”: Communication protocol option menu Select “2: PROTOCOL” to display the screen shown on the right. The highlighted settin
75 Barcode Handy Terminal “3: COM PORT”: Setting the interface port 1. Select “3: COM PORT” at the SET COMMUNICATION menu and then press the ENT k
viii Barcode Handy Terminal Handling the battery cartridge Never disassemble or heat the battery cartridge, nor put it into fire or water; doing s
76 BHT-604BW “4: PROTOCOL TYPE”: Setting the communication protocol type 1. Select “4: PROTOCOL TYPE” at the SET COMMUNICATION menu and then press
77 Barcode Handy Terminal Select “1: Ymodem” at the PROTOCOL TYPE menu to display the screen on the right. The highlighted settings will be the curre
78 BHT-604BW Select “3: BHT-Ir Protocol” at the PROTOCOL TYPE menu to display the screen on the right. Enter the ID number of the BHT using the nume
79 Barcode Handy Terminal [6] Defining the functions of the Shift key and Magic keys Use the following procedure to change the key settings. 1. Sele
80 BHT-604BW “2: M1 KEY” - ”7: M6 KEY”: Defining the Mx key functions 1. Select “2: M1 KEY” to “7: M6 KEY” at the SET KEY menu and then press the
81 Barcode Handy Terminal [7] Setting the resume function Use the following procedure to set the resume function. 1. Select “7: RESUME” at the SET S
82 BHT-604BW [9] Setting the TCP/IP, FTP and DHCP Use the following procedure to change the TCP/IP, FTP and DHCP settings. 1. Select “9: TCP/IP” at
83 Barcode Handy Terminal “2: IP ADDRESS”: Setting the IP address Select “2: IP ADDRESS” at the SET TCP/IP menu to display the screen on the right wh
84 BHT-604BW Setting the FTP 1. Select “2: SET FTP” at the SET TCP/IP menu and then press the ENT key. The SET FTP menu screen displays as shown o
85 Barcode Handy Terminal “2: OPTION”: Setting the FTP options Select “2: OPTION” at the SET FTP menu to display the screen on the right where the cu
Comments to this Manuals