Denso Power Net Terminal BHT-103 Specifications Page 499

  • Download
  • Add to my manuals
  • Print
  • Page
    / 577
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 498
Chapter 18. TCP/IP
491
Syntax:
CALL "SOCKET.FN3" .fcTCnnSys INTERFACE%
Description: This function connects the TCP/IP communications pathway based on the
system settings.
Parameters:
INTERFACE% Communications pathway
Return value: (None)
Run-time errors:
.fcTCnnSys Connect TCP/IP communications pathway with system
settings
Error code Meaning
34h
Communications device file not open
101h
Cannot connect to communications pathway
102h
Communications pathway not specified
103h
Communications pathway already connected
105h
Power-off detected
216h
A parameter is invalid.
503h
The CU has been linked with any other BHT.
504h
LAN-support CU setting being made.
505h
Timeout
Page view 498
1 2 ... 494 495 496 497 498 499 500 501 502 503 504 ... 576 577

Comments to this Manuals

No comments