[3.5] Power Management
Double-tap the "Power Management", and the Power Management
property appears.
You can set the automatic power-off timer, the standby timer, and
CPU clock.
Automatic Power-Off Time:
Battery Power: For the BHT being out of the CU, set the
automatic power-off timer. (Default: 180)
External Power: For the BHT placed in the CU, set the
automatic power-off timer. (Default: 0)
The entry range for the above items is from 0 to 32767 in units o
f
seconds. Specification of 0 disables the automatic power-of
f
facility.
When the “Enable automatic power off with wireless
communication” check box is selected, the power turns OFF
automatically when not performing communication, even if a
wireless connection is open.
Switch to Standby Mode:
Timer (x100 ms): Set the waiting time to switch to the standby
mode within the range from 0 to 32767 in
units of 100 ms. (Default: 10, 100 ms x 10 = 1
second)
CPU Performance:
Normal: Select Normal to operate the CPU at typical
clock speed. (Default)
Fast: Select Fast to operate the CPU at highe
r
clock speed.
Setting the CPU performance to Fast consumes much power, decreasing the BHT operation period
after battery charge.
CPU performance settings will be functional after the setting changes are made.