Chapter 4 Speed, Acceleration and Deceleration Designation
4-17
4.7.2.2 Setting Internal Mode
Set this mode by executing the conventional language library aspChange. For
details, refer to “22.1.2 aspChange.”
4.7.3 Setting Robot Installation Condition
This is a setting for floor installation use and for gantry use. Set “0” for floor
installation and “1” for gantry use. Before shipping, it is set to “0” (floor
installation). This setting must be changed if the robot is to be installed on the
ceiling.
n
nn
n Setting with the Teach Pendant
Operation flow: Main screen
[F2 Arm]
[F6 Aux.]
[F7 Config.]
If you use the teach pendant and follow the above procedure, the User
Preferences window will appear where you can set master control parameters
such as the control set of motion optimization and the mass of payload. Refer
to the " SETTING-UP MANUAL, Section 2.10 “.
Select the "Floor-mount or Overhead-mount" item in this User Preferences
window, then press [F5 Change.] to call up the numeric keypad where you can
enter new values.
Set “0” or “1”: otherwise, the following error occurs: 6003 Excess in effective
value range.