Denso RC5 Specifications Page 368

  • Download
  • Add to my manuals
  • Print
  • Page
    / 692
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 367
12-92
ST_ResetCompRate (Statement) [Ver.1.9 or later]
Function
Initializes the compliance rates (exclusively designed for 6-axis robots).
Format
ST_ResetCompRate
Explanation
Initializes the compliance rates along and about X, Y, and Z axes to 100%.
Related Terms
ST_SetCompRate
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm semaphore obtained, Error
"21F7 Cannot take arm semaphore" will result.
(2) This statement is not executable under the compliance control. If this command
is executed under the compliance control, Error " 60F9 Improper compliance
set/reset operation" will result.
Example
ST_ResetCompControl 'Disable the compliance control
ST_ResetCompRate 'Initialize the compliance rates
Page view 367
1 2 ... 363 364 365 366 367 368 369 370 371 372 373 ... 691 692

Comments to this Manuals

No comments