Denso RC5 Specifications Page 643

  • Download
  • Add to my manuals
  • Print
  • Page
    / 692
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 642
Chapter 21 Vision Control (Option)
21-91
Note (1): Designate the process range with the window.
Note (2): If the position of the designated window is not on the screen,
an execution error will result.
Note (3): The shape of the window available to designate is a rectangle
with 0 degrees. If you designate any shape other than this, an
error occurs.
Note (4): The processing object is the screen designated with
VISWORKPLN.
Note (5): When this command is executed, the process screen 3
(VISWORKPLN 3) is used as a work area and data on the
process screen 3 are not guaranteed. Also, you cannot use
the process screen 3 for processing.
Note (6): The following data can be obtained with the processing result
obtaining function.
Note (7): For this instruction, a µ
µµ
µVision board (option) is required.
Note (8): If the search range of a designated window is wide and the
radius is small, the processing time increases and a timeout
error may occur.
Related Terms
WINDMAKE, VISWORKPLN, VISGETNUM, VISSTATUS, SHDEFCIRCLE
VISSTATUS (n)
n Item
0 Execution Result 0 = Normal -1 = Abnormal
1 Number
2 Execution Time
VISGETNUMa, b
b a = 0~511
0 Number
1 X Coordinate Value
2 Y Coordinate Value
3 unknown
4 Level
5 unknown
6 unknown
7 unknown
8 unknown
9 unknown
Page view 642