2.4.5 User Output Commands
There are three types of user output commands, SET, RESET and OUT. The SET and
RESET commands turn ON and OFF all user outputs specified by I/O type variables.
The OUT command outputs data to a specified user output.
SET Command
The SET command turns ON all user outputs specified by I/O type variables.
For further information about the SET command, refer to the PROGRAMMER'S
MANUAL (I), Chapter 13, Section 13.1 "SET."
RESET Command
The RESET command turns OFF all user outputs specified by I/O type variables.
For further information about the RESET command, refer to the PROGRAMMER'S
MANUAL (I), Chapter 13, Section 13.1 "RESET."
OUT Command
The OUT command outputs data to the user output specified by an I/O type variable.
For further information about the OUT command, refer to the PROGRAMMER'S
MANUAL (I), Chapter 13, Section 13.1 "OUT."
2.4.6 Note When Using Input Signals
When using an input signal (e.g. IO[34]) as a trigger signal to check the state of another
input signal (e.g. IO [35]) as shown in the example below, the data (e.g. IO[34]) should
be set at least 1 msec before.
NOTE: See also Chapter 3, Subsection 5.2.1 "General Information about Processing"
and Chapter 4, Subsection 4.2 "Operation Preparation Start (Input)" for related
explanations.
When there is chattering in the input signal (e.g. relay contact), the length of A should
be made longer.
Important Note When Using Input Signals
1 msec or more