3.5.3.6
Type I Variable Read (0110)
(1) Function
This command outputs to the status area the value of the Type Ι (integer
type) global variable of the number specified in data area 1.
(2) Format
Command area (4 bits, input)
0110
Data area 1 (8 bits, input)
The number of the Type I variable for which a value will be substituted. Any
number between I [0] and I [255] can be specified. When the input data in
data area 1 is nn, the value specified in data area 2 will be substituted for
the Type I variable I [nn].
Data area 2 (16 bits, input)
Nothing will be input.
Status area (16 bits, output)
The lower 16 bit value of the Type I variable specified in data area 1 will be
output.
(3) Description
The value of the Type I variable specified in data area 1 is output to the
status area.
Although the Type I variable has a storage area of 32 bits, the lower 16 bits
will be output to the status area.
Therefore, any value between -32768 and 32767 can be output properly.
However, if the value is out of this range, only the lower 16 bits of the data
will be output.