Connection and Disconnection Procedures
Procedure
Steps
(A)
Step 1 Select the AUTO mode, and activate an emergency stop.
Step 2 Disconnect the connector from CN5 on the robot controller.
Step 3 Connect the connector used for pendantless operation to
CN5 of the robot controller.
Step 4 Error 2187 occurs. Clear it from the external device.
(B)
Step 1 Select the AUTO mode, and activate an emergency stop.
Step 2 Perform disconnection. See the SETTING-UP MANUAL,
Section 5.9, "Preparing the Robot Controller to Unplug the
Teach Pendant."
Step 3 Disconnect the connector from CN5 on the robot controller
within 15 seconds.
Step 4 Connect the connector for Pendantless operation to CN5
on the robot controller.
(C)
Step 1 Set the mode selector switch on the operating panel to TP.
Step 2 Set the mode selector switch on the teach pendant to
AUTO, and activate an emergency stop.
Step 3 Perform disconnection. See the SETTING-UP MANUAL,
Section 5.9, "Preparing the Robot Controller to Unplug the
Teach Pendant."
Step 4 Disconnect the teach pendant from the operating panel
within 15 seconds.
Step 5 Connect the connector used for Pendantless operation to
the operating panel.
Step 6 Set the mode selector switch on the operating panel to
MANUAL.
(D)
Step 1 Disconnect the connector used for pendantless operation
from CN5 on the robot controller.
Step 2
Connect the operating panel or teach pendant to CN5 on the
robot controller.