8.7 Error Code Table
Here, only the error codes relative to DeviceNet communication errors are described
in the table below. For other error codes, refer to the ERROR CODE TABLES, "2
Controller Error Code Table."
DeviceNet Error Code Table
LEDs
Error code What has happened: What to do:
MS NS
1201 Preparing for communications (link not
established)
The DeviceNet module is working normally,
but has not established link with the master
device.
Establish the link from the master
device.
GG
1202 Preparing for communications (link not
established)
The DeviceNet module is working normally
and has established explicit link with the
master device, but not established an I/O
link.
Establish the I/O link from the master
device.
GG
1203 Preparing for communications
(communications idling)
The DeviceNet module is working normally,
but cannot receive data except empty data
from the master device.
Check the contents of I/O data that
the master device sends.
GG
1204 Preparing for communications (I/O timeout)
The DeviceNet module is working normally,
but cannot receive data from the master
device within the specified time.
Check that the DeviceNet cable is
not broken or its connector is firmly
plugged in.
Check the DeviceNet cable length
and that a terminator resistor is
attached to each end of the trunk
line.
GR
1205 Initial setting error in the communications
processor
Failed to establish the initial link with the
DeviceNet communication processor.
Turn the controller power off and then
on, and do the same operation again.
−−
1210 A DeviceNet internal communications error has
occurred.
Turn the controller power off and then
on, and do the same operation again.
−−
1213 The network is broken or "bus off."
The DeviceNet cable is broken or not
connected.
Check whether the DeviceNet cable
is connected with the robot controller.
If this error occurs after you change
the DIP switch setting, check whether
the bit rate setting made with the DIP
switch matches the network's bit rate.
GR
1215 Preparing for communications (Initial setting
error)
No initial settings have been received from
the robot.
Check whether the bit rate setting
made with the DIP switch matches
the network's bit rate..
G
1216 Data length setting error
DeviceNet INSLOT or OUTSLOT is not 32 or
less.
Turn the controller power off and then
on. Then, set correct DeviceNet
INSLOT and OUTSLOT values.
R
1217 Node address double-assign error
The same node address is double assigned
to the robot controller and any other online
node.
Assign an exclusive node address to
each node (including the robot
controller) on the same DeviceNet.
GR
: ON : Flashing : OFF – : Indefinite