Denso RC5 Specifications Page 85

  • Download
  • Add to my manuals
  • Print
  • Page
    / 138
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 84
73
9.4 Building Up a DeviceNet Network
9.4.1 Network Configuration Sample and Configurators
Nodes
A DeviceNet network has two kinds of nodes: slaves to which external I/Os are
connected, and a master that controls these slaves. Note that their addresses are
just network settings, so the master and slaves can be freely arranged on physical
sites.
Trunk lines and drop lines
The trunk line is a cable whose both ends are terminated with resistors.
A drop line is a cable that branches off the trunk line.
The trunk line and drop lines can be constructed using DeviceNet thick cables,
DeviceNet thin cables, or both.
Thick cables are used for long-distance trunk lines, strong trunk lines, and drop lines.
Thin cables are used for trunk lines and drop lines, and for easy termination
processing.
Terminating resistors
Terminating resistors must be connected at both ends of the trunk line in a DeviceNet
system. The specifications of the terminating resistors are listed below.
121
Metal film resistor with resistance error of less than 1%
1/4 W
Never connect a terminating resistor to a node. This may result in a failure.
Page view 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 137 138

Comments to this Manuals

No comments