105
Step 3
On the screen shown in Step 2, press [OK]. The system message window will
appear as shown below.
Turn the controller power off and on. Then the new settings will take effect.
10.3.2 Configuring the Robot Controller from the PC with the
PROFIBUS Configurator
Configure the robot controller (node address and I/O module) by using the
PROFIBUS configurator (GSD file) stored in the CD-ROM that comes with the
PROFIBUS slave board.
CD-ROM:\EDS\PROFIBUS\GSD\Hil_7504.gsd
You may also download the GSD file from the PROFIBUS website as shown below.
http://www.profibus.com
GSD Library Company “Hilscher” Device Type “General”
CIF30-DPS Hil_7504.GSD
I/Os expressed in the PROFIBUS configurator are viewed from the master device.
Therefore, they are opposite of those viewed from the robot controller and are the
same as viewed from the teach pendant, as listed in Subsection 10.3.1.
When configuring the robot controller on the PC with the PROFIBUS configurator, set
the same module as one selected on the teach pendant screen. Slot 0 and Slot 1
should be equal to "n byte Output con" and "n byte Input con," respectively.
NOTE: The robot controller may use a coherent type of module only. The GSD file
contains both programs for coherent and incoherent types, so be sure to choose the
program exclusive to the coherent type. (The program name contains a "con" string.)
NOTE: Some master device programs use special functions when exchanging data
with a coherent type of module. For details, refer to the instructions manuals
prepared for master devices.