Chapter 21 Vision Control (Option)
21-47
VISBINA (Statement)
Function
Binarizes the screen.
Format
VISBINA <Window number>, <Coordinate X>, <Coordinate Y>, <Binary lower
limit>[, <Binary upper limit>]
Explanation
<Window number> Designates the window number (0 to 511).
<Coordinate X> Designates the X coordinate (0 to 511).
<Coordinate Y> Designates the Y coordinate (0 to 479).
<Binary lower limit> Designates the upper level for binarization
(0 to 254 lower limit < upper limit).
<Binary upper limit> Designates the upper level for binarization
(1 to 255 lower limit < upper limit).
If this is ignored, 255 will be the default setting.
Example of binarization
Note (1): Designate the process area with a window.
Note (2): If the designated window position is out of screen, the
execution will result in an error.
Note (3): The only possible window shape that may be designated is
a rectangle with 0 degrees. If another window shape is
designated, an error will result.
Note (4): The processing object is the screen designated with
VISWORKPLN.
Note (5): For this instruction, a µ
µµ
µVision board (option) is required.
Related Terms
WIMDMAKE, VISWORKPLN
Binarization
processing
Page view 598
1 2 ... 594 595 596 597 598 599 600 601 602 603 604 ... 691 692