Chapter 2 Program Flow
2-5
2.2 Running a Program
The following 3 methods are available for running a program.
Start using teach pendant operation.
Start using the operating panel.
Start by using I/O from an external device.
As explained below, there are limitations to running a program depending on
the running method.
For the method by which the started program calls another program, refer to
“2.1 Calling a Program and Subroutine”.
2.2.1 Running from the Teach Pendant
To run a program from the teach pendant, use teach check mode or internal
automatic mode.
The programs that can be started are limited to programs that do not include
any arguments. A program with any type of program name can be started.
2.2.2 Running from the Operating Panel
Use internal automatic mode to run a program from the operating panel.
The programs that can be started are limited to ones with a name that
conforms to the “PRO< number >” format.
Note (1): The mode cannot be changed to teach check mode from the
operating panel.
Note (2): A program with a program name format of “PRO< number >”
cannot include arguments.
2.2.3 Running from an External Device
In external automatic mode, a program can be run with input from external I/O.
The programs that can be started are limited to the ones with a program name
in the “PRO< number >” format.
The programs that can be started from an external device is limited to
programs PR00 to PR032767 in standard mode and PR00 to PR0127 in
compatible mode.
Note: A program with a program name format of “PRO< number >”
cannot include arguments.