Denso RC5 Specifications Page 620

  • Download
  • Add to my manuals
  • Print
  • Page
    / 692
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 619
21-68
Note (1): Designate the process range with a window.
Note (2): If the designated window position is out of screen, the
execution will result in an error.
Note (3): The only window shape you are able to designate is a
rectangle with 0 degrees. If another window shape is
designated, an error will result.
Note (4): The processing object is a screen designated with
VISWORKPLN.
Note (5): The following data can be obtained with the process result
obtaining function.
Note (6): For this instruction, a µ
µµ
µVision board (option) is required.
Related Terms
WINDMAKE, VISWORKPLN, VISGETNUM, VISSTATUS
VISSTATUS (n)
n Item
0 Execution result 0=Normal
-1=Abnormal
1 Number of labels
2 Execution time
VISGETNUM (a, b)
b a = 0~ max511
0Area
1 Center of gravity a
coordinate X value
2 Center of gravity a
coordinate Y value
3 unknown
4 Filet dia. reference point
coordinate Y
5 Filet dia. reference point
coordinate X
6 Filet dia. width
7 Filet dia. height
8 unknown
9 unknown
Page view 619