22-16
No. Items
Factory
default
Powering-on
default
Description Comments
53
to
60
Gain reduce rate
(J1 to J8)
Value
proper
to each
robot
Last value at
powering-off
Gain reduction rate for one of J1 to J8
Takes effect
when the
"Changing accel
mode," "Control
method" and
"High-inertia
configuration"
are set to 0. Do
not change the
initial value.
61
to
68
High-inertia load
operation gain reduce
rate (J1 to J8)
(For HM/HS-D series)
0 Last value at
powering-off
Gain reduction rate for one of J1 to J8
when the high-inertia load operation is
selected
Takes effect
when the
"Changing accel
mode" and
"Control method"
are set to 0 and
"High-inertia
configuration" is
set to 1. Do not
change the initial
value.
69 New type robot or old
type robot
(For 4-axis robot)
0 Last value at
powering-off
0: New type (D series)
1: Old type (C series)
If you purchase
the controller
alone to
connect it to the
HM/HS/HC-C
series, set this
item to 1.
70 Pass motion setting 0 Last value at
powering-off
When restarted after any stop operation
during pass motion, the robot will make
motion towards:
0: Target position specified after the
pass motion (Default)
1: Target position specified before the
pass motion
71 Positioning allowance
of pass end
5 Last value at
powering-off
Condition for preventing the robot from
taking motion towards the target
position specified before pass motion,
when the robot is restarted
The condition should be set as a
distance from the target position.
The condition
refers to a
distance from
the target
position at the
command level,
not the actual
distance from
the current
robot end
position.
78
Damper setting rate
(X)
(For 6-axis robot)
10000 10000
Damping ratio along the X-axis under
compliance control
79
Damper setting rate
(Y)
(For 6-axis robot)
10000 10000
Damping ratio along the Y-axis under
compliance control
80 Damper setting rate
(Z)
(For 6-axis robot)
10000 10000 Damping ratio along the Z-axis under
compliance control
Can be set with
SetDampRate or
ResetDampRate.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)